Cummins — 4021330

Heat Exchanger C8.3 Industrial Page 6-12 Section 6 - Maintenance Procedures at 300 Hours or 1 Year Remove the zinc plugs from the aftercooler and heat exchanger. Typical hose connections are shown. Disconnect the sea water inlet and outlet connection from the heat exchanger. Refer to 100-002 (Engine Diagrams) in Section E. Use clean low-pressure water to backflush the heat exchanger. Connect the hose to the heat exchanger sea water outlet to allow the water to backflush the system. This will remove and flush away any loose debris. Make sure the end cavities are cleared of all debris. Inspect each plug. If either plug has eroded over 50 percent, it must be replaced.

Erosion Limits New A = Approximately 19 mm [0.75 in] 51 mm [2 in] B = Approximately 6.4 mm [0.25 in] 16 mm [0.63 in]