Cooling Fan Belt Tensioner C8.3 Industrial Page 8-8 Section 8 - Maintenance Procedures at 600 Hours or 2 Years Fill The system must be filled properly to prevent air locks. During filling, air must be purged from the engine coolant passages. Be sure to open the petcock on the aftercooler for aftercooled engines. Wait 2 to 3 minutes to allow air to be vented; then add mixture to bring the level to the top. CAUTION The system is designed to use a specific quantity of coolant. If the coolant level is low, the engine will run hot. If frequent addition of coolant is necessary, the engine or system has a leak. Find and repair the leak.
The system has a designed fill rate of 19 liters [5 gal] per minute. Never use water alone for coolant. This can result in damage from corrosion. CAUTION Use a mixture of 50-percent water and 50-percent ethylene glycol or propylene glycol antifreeze to fill the cooling system. Coolant Capacity (Engine Only) liters U.S.gal 6C 8.3 Engine 10.9 MAX 11.5 WARNING Do not remove the pressure cap from a hot engine. Wait until the coolant temperature is below 50° C [120° F] before removing the pressure cap. Heated coolant spray of steam can cause personal injury. Install the pressure cap. Operate the engine until the coolant reaches a temperature of 80°C [180°F], and check for coolant leaks.
Check the coolant level again to make sure the system is full of coolant or that the coolant level has risen to the hot level in the recovery bottle on the system, if so equipped. Cooling Fan Belt Tensioner Maintenance Check Every 48,000 km [30,000 mi], 1000 hours, or 1 year, whichever occurs first, inspect the automatic belt tensioner. With the engine turned off, check that neither the top nor bottom tensioner arm stop is touching the cast boss on the tensioner body. If either of the stops is touching a boss, the alternator belt must be replaced. Check to make sure the correct belt part number is being used if either condition exists.