Cooling System C8.3 Industrial Page 10-4 Section 10 - Maintenance Procedures at 2000 Hours or 2 Years The system must be filled properly to prevent air locks. During filling, air must be purged from the engine coolant passages. Be sure to open the petcock on the aftercooler for aftercooled engines. Wait 2 to 3 minutes to allow air to be vented; then add water to bring the level to the top. CAUTION Fill the cooling system with high-quality water. Do not install the radiator cap or the new coolant filter. Operate the engine for 5 minutes with the coolant temperature above 80°C [176°F]. Shut the engine off, and drain the cooling system.
If the water being drained is still dirty, the system must be flushed again until the water is clean. Fill The system must be filled properly to prevent air locks. During filling, air must be purged from the engine coolant passages. Be sure to open the petcock on the aftercooler for aftercooled engines. Wait 2 to 3 minutes to allow air to be vented; then add mixture to bring the level to the top. CAUTION The system is designed to use a specific quantity of coolant. If the coolant level is low, the engine will run hot. If frequent addition of coolant is necessary, the engine or system has a leak. Find and repair the leak. The system has a designed fill rate of 19 liters [5 gal] per minute.
Never use water alone for coolant. This can result in damage from corrosion. CAUTION Use a mixture of 50-percent water and 50-percent ethylene glycol or propylene glycol antifreeze to fill the cooling system. Coolant Capacity (Engine Only) liters U.S.gal 6C 8.3 Engine 10.9 MAX 11.5