Cummins — 4021330

C8.3 Industrial Troubleshooting Symptoms Charts Section TS - Troubleshooting Symptoms Page TS-35 Engine Starts But Will Not Keep Running Cause Correction STEP 1 Fuel level is low in the tank ............. Fill the supply tank. Refer to the OEM service manual. OK Go To Next Step STEP 2 Idle speed is set too low for accessories ............. Check and adjust the low-idle screw. Refer to the OEM service manual. OK Go To Next Step STEP 3 Engine-driven units are engaged ............. Disengage engine-driven units. OK Go To Next Step STEP 4 Fuel shutoff lever (mechanical) partially engaged ............. Check for correct solenoid operation. Refer to the OEM service manual.

OK Go To Next Step Check for air in the fuel system. Tighten or replace the fuel connections, fuel lines, fuel tank standpipe and fuel filters as necessary. Vent air from the system. Refer to Procedure 006-003 (Air in Fuel) in Section A. STEP 5 Air in the fuel system ............. OK Go To Next Step STEP 6 Fuel filter or fuel suction line is restricted ............. Replace the fuel filter. Refer to Procedure 006-015 (Fuel Filter (Spin on Type)) in Section 6. OK Go To Next Step STEP 7 Fuel supply line or passage restriction between the ............. Check the fuel supply line or passage for sharp bends or restriction.

Procedure 006-024 (Fuel Supply Lines) in Section A fuel pump and the injectors OK Go To Next Step Operate the engine from a tank of high-quality fuel. Refer to Procedure 018-002 (Fuel Recommendations and Specifications) in Section V. STEP 8 Fuel grade is not correct for the application or the ............. fuel quality is poor OK Go To Next Step STEP 9 Contact a Cummins® Authorized Repair Facility