Component Connector and Pin Inspection C8.3 Industrial Page 4-6 Section 4 - Maintenance Procedures at 75 Hours, or 3 Months Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last. WARNING Install the cables and tighten the battery connections. Coat the terminals with grease to prevent corrosion.
Component Connector and Pin Inspection General Information The following inspection procedures should be used for any component, connector, or harness connector to ensure there is no pin damage. Inspect for Reuse When disconnecting connectors during troubleshooting, always check for loose connectors (gently pull the wires at the back of the connector) and inspect the pins to make sure they are not the cause of a bad connection. The things to look for are bent, corroded, and pushed back pins. Moisture in Connector Moisture in a connector can also cause system performance issues. Many times it is difficult to see moisture in a connector.
If moisture is suspected, the connector must be dried by applying contact cleaner, Part No. 3824510, to the connector. A heat gun can also be used on a low heat setting so that it will not damage the connector or wires. NOTE: Do not blow compressed air in the electronic control unit ports or connector. Compressed air can contain moisture due to condensation.