Cummins — 4021330

C8.3 Industrial Lubricating Oil and Filters Section 5 - Maintenance Procedures at 250 Hours or 3 Months Page 5-3 The pressure of the fuel in the line is sufficient to penetrate the skin and cause serious personal injury. Wear gloves and protective clothing. WARNING 17-mm (PES.A, PES.MW) and 19-mm (PES.P) Wrenches Loosen the fittings at the injectors, and crank the engine to allow entrapped air to vent from the lines. Tighten the fittings. WARNING It is necessary to put the engine in the run position. Because the engine could start, be sure to follow all the safety precautions. Use the normal engine starting procedure.

Start the engine and vent one line at a time until the engine runs smoothly. NOTE: Do not engage the starter for more than 30 seconds each time when it is used to vent the system: Wait 2 minutes between engagements. Lubricating Oil and Filters Drain WARNING Some state and federal agencies have determined that used engine oil can be carcinogenic and cause reproductive toxicity. Avoid inhalation of vapors, ingestion, and prolonged contact with used engine oil. If not reused, dispose of in accordance with local environmental regulations. PROTECT THE ENVIRONMENT: Handling and disposal of used lubricating engine oil is subject to federal, state, and local laws and regulations.

Use authorized waste disposal facilities, including civic amenity sites and garages providing authorized facilities for receipt of used lubricating oil. If in doubt, contact your state and local environmental authorities or the Environmental Protection Agency for guidance as to proper handling and disposal of used lubricating engine oil.