Deutz — Checking the con rod

Connecting rod TCD 2013 2V W 06-01-02 ●Prepare internal measuring device: Mount probe bolt for the appropriate measuring range in the internal measuring device. Mount dial gauge with approx. 1 mm pre-tension in the internal measuring device. Set micrometer gauge to 72 mm. Balance the internal measuring device between the test surfaces of the micrometer gauge and set the dial gauge at the reversal point of the pointer to "0". 6 © 36094-1 Diagram for measuring the con rod bearing bore at the points "a" and "b" in the levels "1" and "2". © 37239-1 ●Insert internal measuring device.

●Balance the internal measuring device at the given measuring points and read off the measured value at the reversal point of the pointer. 72,5 mm If the measured values deviate slightly, additional measurements must be made with new bearing shells. © 44214-0 © 02/2010 OBJ_DOKU-21762-001.fm 4/8