Connecting rod TCD 2013 2V W 06-01-02 ●Mount big end bearing cap. Attention! Note the assignment of the big end bearing cap. The identification numbers (1) on the con rod and the big end bearing cap must be identical and opposite to each other when assembled. 26519 26519 1 6 © 44217-0 ●Tighten screws alternately with rotation angle disc and socket wrench insert. Stage 1: 50 Nm Stage 2: 60° Stage 3: 60° © 44218-0 ●Prepare internal measuring device: Mount probe bolt for the appropriate measuring range in the internal measuring device. Mount dial gauge with approx. 1 mm pre-tension in the internal measuring device. Set micrometer gauge to 72.5 mm.
Balance the internal measuring device between the test surfaces of the micrometer gauge and set the dial gauge at the reversal point of the pointer to "0". © 36094-1 © 02/2010 OBJ_DOKU-21762-001.fm 6/8