Cummins — ELECTRICAL SYSTEM

MAINTENANCE SECTION 2 Page 51 TROUBLE SHOOTING GUIDE This guide is not intended to cover all conditions, however many of the more common possibilities are listed. ELECTRICAL SYSTEM Lamp flickers while engine runs. . Check for loose terminals and open-circuit wiring + Adjust belt tension. Lamp does not glow brightly even when engine runs at high speed. Charge monitor does not go out even when engine runs at high speed. - Replace the alternator. * Inspect and repair wiring. Unusual noise is emitted from the alternator. - Replace the alternator. Starting motor does not turn when starting switch is turned on. . Inspect and repair the wiring. - Charge the battery.

The pinion of the starting motor keeps going in and out. - Charge the battery. Starting motor turns the engine sluggishly. . Charge the battery. - Replace the starting motor. The starting motor disengages before the engine starts up . Check and repair the wiring. - Charge the battery. The engine preheating monitor does not flash. - Check and repair the wiring. . Replace the heater relay. . Replace the monitor. The engine oil pressure monitor does not light up when engine is stationary (when the starting switch is in ON position.) . Replace the monitor. - Replace the monitor switch. Charge monitor does not light up when the engine is stationary. (When the starting switch is in ON position.) .

Replace the monitor. - Inspect and repair the wiring. Outside the electrical intake air heater is not warm when touched with the hand. . Check and repair the wiring. * Replace the electrical intake air heater. - Check and repair the heater switch.