SERIES 60 SERVICE MANUAL 2.51 VENTING AND LEAK CHECKING PROCEDURES FOR NATURAL GAS ENGINE (LOW PRESSURE SYSTEM) Refer to section 2.51.1 for venting and checking of an operable engine and refer to section 2.51.2 for venting and checking of an inoperable engine. 2.51.1 Venting an Operable Engine to Relieve Natural Gas Pressure If the engine can run , use the following venting procedure to relieve the natural gas pressure downstream of the shutoff valve: EXPLOSION To avoid injury from the explosion of natural gas, the engine must be kept in a well ventilated area away from open flames, sparks, and electrical resistance (heating) coils. 1.
Turn off manual shutoff valve on natural gas fuel supply line. 2. Start engine and run until it stalls due to fuel starvation. 3. Disconnect the batteries using switch(s) in the battery compartment or by disconnecting the battery ground cable. 4. Slightly loosen the NG fuel line fitting to be serviced in a well-ventilated area to allow any remaining gas to vent. 5. Completely open the fitting that was slightly opened and allow to vent in a well-ventilated area. 2.51.2 Venting an Inoperable Engine to Relieve Natural Gas Pressure If the engine cannot run , use the following venting procedure to relieve the natural gas pressure downstream of the shutoff valve:
EXPLOSION To avoid injury from the explosion of natural gas, the engine must be kept in a well ventilated area away from open flames, sparks, and electrical resistance (heating) coils. 1. Turn off manual shutoff valve on natural gas fuel supply line. All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 2-255