4.2 WATER PUMP (GEAR-CASE MOUNTED - 1991 AND LATER) (GCM) 12. Install J–35988–3A (part of tool set J–35988–C) to the fixture tool. See Figure 4-22. Figure 4-22 Support Installation (GCM) NOTICE: The extension must contact and support the shaft when installing the water seal and impeller to prevent damage to the bearings. 13. Install the water pump housing assembly to the fixture. See Figure 4-23. Figure 4-23 Water Pump Impeller Installation Set-up (GCM) 14. Turn the adjustor wheel to raise the extension until it contacts the drive shaft in the water pump housing. 15. Apply Loctite® primer (Locquic Primer N, Part No. 764) by swabbing onto the I.D. of the rotor of the seal. (Rev.
2005) All information subject to change without notice. 4-22 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION