5.4 COOLANT 5.4.8.2 Test Kit Procedures Use Detroit Diesel Powertrac® 2-Way Coolant Test Strips (part number 23515917) to measure nitrite and glycol concentrations. Cavitation/corrosion protection is indicated on the strip by the level of nitrite concentration. NOTICE: Do not use Detroit Diesel Power Cool ™test strips to determine the inhibitor levels of coolant with non-DDC approved additive packages. Incompatible chemicals and variance in inhibitor levels in the additive packages may cause inaccurate interpretation of test strip readings. This can lead to under-inhibiting the coolant, which may result in cavitation erosion.

Freeze and boil over protection is determined by glycol concentration. Use the test strips as follows: 1. Dip the strip into coolant for one second. Remove and shake briskly to eliminate excess fluid. 2. Immediately compare end pad (% glycol) to the color chart. 3. Sixty seconds (one minute) after dipping, compare the nitrite pad to the chart contained within the kit. For best results make the tests while the coolant is between 10 - 60°C (50 - 140°F). Wait at least 60, but not longer than 75 seconds before reading the nitrite level. Promptly replace and tighten container cap after each use. Discard unused strips if they have turned light pink or tan.

A factory coolant analysis program is also available through authorized Detroit Diesel service outlets under part number 23508774. 5.4.9 Summary of Coolant Recommendations Coolant recommendations may be summarized as follows: (Rev. 2005) All information subject to change without notice. 5-28 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION