Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

SERIES 60 SERVICE MANUAL To avoid scalding from the expulsion of hot coolant, never remove the cooling system pressure cap while the engine is at operating temperature. Wear adequate protective clothing (face shield, rubber gloves, apron, and boots). Remove the cap slowly to relieve pressure. HOT COOLANT NOTE: Propylene glycol meeting ASTM D 4985, and ASTM D 5216, is approved for use in Series 60 engines. Always maintain the engine coolant to meet Detroit Diesel specifications. Only use water that meets Detroit Diesel specifications.

Distilled or deionized water is preferred The proper dosage of SCA must be included in the coolant at initial fill for all Detroit Diesel Series 60 engines.This dosage can be either included in part or entirely in the IEG used, or it may need to be added. Dosage is also dependent on whether water or IEG is used. The user is urged to refer to the full text of this bulletin to determine the proper dosage. Mixing of different manufacturers' inhibitors (SCAs) could cause cooling system problems Maintain the SCA to the prescribed concentration. Test the nitrite concentration by using a titration kit or Detroit Diesel 2-Way Coolant Test Strips.

Add SCA only if the nitrite concentration is below 800 ppm Do not use another manufacturer's test kit to measure the SCA concentration of Detroit Diesel Maintenance Products. Pre-mix coolant makeup solutions at the proper concentration before adding to the coolant system. Where antifreeze/boilover protection is required, use only ethylene glycol coolant (low silicate formulation) meeting GM 6038-M, GM 1899-M, or ASTM D 4985. Propylene glycol meeting ASTM D 4985, and ASTM D 5216 is also approved for use in Series 60 engines. Always maintain proper coolant level. All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 5-29