SERIES 60 SERVICE MANUAL 4. Apply specified calibration pressure as listed in Table 6-1, to the wastegate actuator. Garrett® is a registered trademark of Honeywell. BorgWagner Turbo Systems® is a registered trademark of BorgWagner Corportation. Table 6-1 Wastegate Calibrations 5. Close air supply shutoff valve. The pressure should hold at the specified pressure. If not, check air hose and fitting connections for leaks. If none are found, replace wastegate actuator. Refer to section 6.5.4. 6. Open vent to relieve pressure. Check gage for zero pressure reading. Adjust regulator to zero pressure and close vent valve. 7.
Adjust dial indicator so it just contacts the actuator rod end and adjust to zero reading. 8. Open air supply shutoff valve and slowly adjust regulator until dial indicator reads 1.016 mm (0.040 in.) for Garrett® systems and 1.45-2.26 mm (0.057–0.089 in.) for BorgWagner Turbo Systems®. Switch pressure on and off, opening and closing supply air and vent valves, to ensure dial indicator travel is from 0.00–1.016 mm (0.00–0.040 in.) for Garrett® systems or 0.00–2.26 mm (0.00–0.089 in.) for BorgWagner Turbo Systems®; and that the pressure reading is consistent. 9.
For currently calibrated wastegate actuator, a pressure within ± 3.4 kPa (0.50 psi) of the value listed in Table 6-1, will be required to obtain precisely the correct amount of actuator rod travel. If the pressure required is outside this range, wastegate adjustment is necessary. Refer to section 6.5.5.1. All information subject to change without notice. (Rev.
2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 6-35 Manufacturer Model Rating Can Pressure Rod Travel Garrett® 11.1L 330–350 Hp 182.71-189.61 kPa (26.5–27.5 psi) 1.016 mm (0.040 in.) Garrett® 12.7L 330–500 Hp 210.29-217.19 kPa (30.5–31.5 psi) 1.016 mm (0.040 in.) Garrett® 14.0L 550–575 Hp 210.29-217.19 kPa (30.5–31.5 psi) 1.016 mm (0.040 in.) BorgWagner Turbo Systems® 12.7 330–430 Hp 234.22-234.63 kPa (33.97–34.03 psi) 1.45-2.26 mm (0.057–0.089 in.)