6.5 TURBOCHARGER (DIESEL) For Series 60 engines with Exhaust Gas Recirculation (EGR) systems install the VNT turbocharger as follows: 1. Place base gasket over studs on exhaust manifold. 2. Place turbocharger over studs. 3. Install four M10 nuts and washers and torque to 49 N·m (36 lb·ft). 4. Connect air line to VNT actuator and torque to 20 N·m (15 lb·ft). 5. Install turbocharger compressor outlet temperature sensor. 6. Install turbocharger speed sensor. Refer to section 2.22. Connect air line from variable pressure output device (VPOD) to actuator on VNT. (Rev. 2005) All information subject to change without notice. 6-42 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION