SERIES 60 SERVICE MANUAL 4. Apply specified calibration pressure (listed in Table 6-2) to the wastegate actuator. Table 6-2 Series 60G Wastegate Calibration Pressure at 0.04 in. Rod Travel NOTICE: For genset turbochargers, NEVER apply pressure to bottom part of actuator can. Damage to actuator may result. 5. Close air supply shutoff valve. The pressure should hold at the specified pressure. If not, check air hose and fitting connections for leaks. If none are found, replace wastegate actuator assembly. Refer to section 6.6.5. 6. Open vent to relieve pressure. Check gage for zero pressure reading. Adjust regulator to zero pressure and close vent valve. 7.

Adjust dial indicator so it just contacts the actuator rod end and adjust to zero reading. 8. Open air supply shutoff valve and slowly adjust regulator until dial indicator reads 0.040 in. Switch pressure on and off, opening and closing supply air and vent valves, to make certain dial indicator travel is from 0.00 in. to 0.040 in. and that the pressure reading is consistent. 9. For currently calibrated wastegate actuator, a pressure within ± 1.72 kPa (0.25 psi) of the value listed in Table 6-2, will be required to obtain precisely 0.040 in. actuator travel. If the pressure required is outside this range, wastegate adjustment is necessary; refer to section 6.6.5.

All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 6-55 Model Rating Set Pressure Travel at 1.0 mm (0.04 in.) Rod Coach 330 Hp 165 kPa (24 psi)