8.1 TUBE AND SHELL BOLTED FLANGE EGR COOLER 8.1.1.1 Inspection and Testing the Tube and Shell Bolted Flange EGR Cooler Engines equipped with a TSBF cooler that have a coolant-lost complaint need to be inspected for leaks from other sources. The spring wire hose clamps are a possible coolant leak path, and should be inspected. If the spring wire clamps are damaged, service kits are available to replace the damaged components. A standard test to pressurize the coolant system and investigation of overall coolant system should have been performed prior to inspecting the cooler. There may be other components of the engine that are responsible for the loss of engine coolant. NOTE:

Coolers with internal leaks usually show signs of a white coolant drop-out at the exhaust side of the cooler, the Delta P Sensor lines, or at the delivery pipe to intake manifold connector. If the entire system has been tested, perform the following steps to inspect the cooler: 1. Use hoses, clamps, plugs, and a regulator to seal the cooler water inlet and water outlet ports. See Figure 8-7. Figure 8-7 EGR Cooler Ports Setup (Rev. 2005) All information subject to change without notice. 8-10 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION