SERIES 60 SERVICE MANUAL 2. Fill the exhaust side of the cooler with hot tap water. Allow the water to overflow until the loose carbon has floated away allowing for a clear viewing of any bubbles. See Figure 8-8. Figure 8-8 Filling the EGR Cooler with Tap Water 3. Apply 207 kPa (30 psi) of regulated air to the regulator for three minutes. See Figure 8-7. 4. Disconnect the regulated air supply from the regulator and watch for bubbles on the exhaust side of the cooler. See Figure 8-9. [a] If bubbles were observed, replace the cooler. [b] If no bubbles were observed, contact the Detroit Diesel Customer Support Center for further information (313-592-5800).
Figure 8-9 Observing the EGR Cooler for Bubbles 8.1.2 Installation of the Tube and Shell Bolted Flange EGR Cooler Installation steps are as follows: All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 8-11