Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

SERIES 60 SERVICE MANUAL 2. Fill the exhaust side of the cooler with hot tap water. Allow the water to overflow until the loose carbon has floated away allowing for a clear viewing of any bubbles. See Figure 8-8. Figure 8-8 Filling the EGR Cooler with Tap Water 3. Apply 207 kPa (30 psi) of regulated air to the regulator for three minutes. See Figure 8-7. 4. Disconnect the regulated air supply from the regulator and watch for bubbles on the exhaust side of the cooler. See Figure 8-9. [a] If bubbles were observed, replace the cooler. [b] If no bubbles were observed, contact the Detroit Diesel Customer Support Center for further information (313-592-5800).

Figure 8-9 Observing the EGR Cooler for Bubbles 8.1.2 Installation of the Tube and Shell Bolted Flange EGR Cooler Installation steps are as follows: All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 8-11