8.1 TUBE AND SHELL BOLTED FLANGE EGR COOLER 20. Install the oil inlet and outlet fittings to the hydraulic actuator assembly. Torque the fittings to 24-28 N·m (18-21 lb·ft). See Figure 8-14. 1. EGR Valve and Hydraulic Actuator Assembly 3. Oil Inlet Line and Fitting 2. Oil Outlet Line and Fitting Figure 8-14 EGR Valve and Hydraulic Actuator Assembly (Rev. 2005) All information subject to change without notice. 8-16 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION