Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

SERIES 60 SERVICE MANUAL 21. Install air line fitting to the pneumatic actuator assembly. Torque to 19-22 N·m (14-16 lb·ft). See Figure 8-15. 1. EGR Valve and Pneumatic Actuator Assembly 2. Air line Tube Figure 8-15 EGR Valve and Pneumatic Actuator Assembly 8.1.2.1 Checking Pneumatic Actuator Assembly Calibration Measure pneumatic actuator rod end travel as follows. 1. Install a dial indicator. 2. Adjust the stem of the dial indicator to rest on the rod end of the pneumatic actuator assembly. See Figure 8-16. 3. With the valve closed and no pressure to the actuator set the dial indicator to zero.

EYE INJURY To avoid injury from flying debris when using compressed air, wear adequate eye protection (face shield or safety goggles) and do not exceed 276 kPa (40 psi) air pressure. 4. Using shop air, a pressure regulator and pressure gage, increase pressure at the actuator to 152 kPa (22.0 psi). Rod end travel with 152 kPa (22.0 psi) at the actuator should measure between 0.69-0.83 mm (0.027-0.033 in.). All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 8-17