8.1 TUBE AND SHELL BOLTED FLANGE EGR COOLER 5. If calibration is not correct, adjust by loosening the jam nut and rotating the adjuster COUNTER CLOCKWISE to INCREASE the dial indicator reading or CLOCKWISE to DECREASE the dial indicator reading.. See Figure 8-16. 2. Rod End 5. Pneumatic Actuator Assembly 1. EGR Valve Assembly and Pneumatic Actuator Assembly 4. Jam Nut 3. Adjuster Figure 8-16 Pneumatic Actuator Assembly NOTE: Tightening the jam nut will stretch the rod end and change the calibration setting. After adjustment the rod end should be checked with the jam nut tightened. The torque specification for the jam nut is 25-28 N·m (18.4-20.7 lb·ft). Repeat step 5 if necessary. (Rev.
2005) All information subject to change without notice. 8-18 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION