Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

8.4 EGR RATE MEASUREMENT SYSTEM 8.4 EGR RATE MEASUREMENT SYSTEM The EGR Rate Measurement system provides DDEC with measurements resulting in EGR flow rate prediction. The EGR Rate Measurement system consists of a venturi tube with a Delta P Sensor and a Exhaust Gas Temperature Sensor. Pressure differential between the venturi tube inlet, throat and along with exhaust gas temperature are converted to mass flow rate in DDEC. The venturi tube is a component of the delivery pipe. 8.4.1 Removal of EGR Rate Measurement System Removal steps are as follows: PERSONAL INJURY To avoid injury from hot surfaces, wear protective gloves, or allow engine to cool before removing any component. 1.

Remove connector at Delta P sensor. (Rev. 2005) All information subject to change without notice. 8-40 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION