SERIES 60 SERVICE MANUAL 2. Install bracket (11) onto the thermostat housing (12). See Figure 8-37. 1. Delta P Sensor 6. Fitting Nut 10. Nut 2. Stud 7. Venturi Tube 11. Bracket 3. Isolator 8. Clip 12. Thermostat Housing 4. Hose Clamp 9. Delta P Tube 13. Bolt 5. Delta P Tube Figure 8-37 Delta P Sensor and Related Parts 3. Install remaining three isolators (3) over studs (2) and secure bracket (11) and isolators (3) to the thermostat housing with nuts.See Figure 8-37. Torque nuts to 23-27 N·m (17-20 lb·ft). 4. Install the Delta P Sensor (1) to bracket (11) and secure with bolts (13). See Figure 8-37. Torque bolts to 30-38 N·m (22-28 lb·ft). 5.
Install the hose clamps (4) to the Delta P Sensor (1) and to the Delta P tubes (5 and 9). See Figure 8-37. 6. Insert the Delta P tubes (5 and 9) to the Delta P Sensor (1) and secure with hose clamps (4). See Figure 8-37. 7. Connect the Delta P tubes (5 and 9) to the venturi tube (7). See Figure 8-37. 8. Secure the P-clips (8) to the exhaust manifold and secure with bolts. See Figure 8-37. Torque the bolts to 30-38 N·m (22-28 lb·ft). 9. Torque Delta P tube fitting nuts (6) to 24-30 N·m (18-22 lb·ft). Connect Delta P sensor connector at sensor. All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 8-43