Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

8.5 DDEC V VARIBLE PRESSURE OUTPUT DEVICE 8.5 DDEC V VARIBLE PRESSURE OUTPUT DEVICE The Variable Pressure Output Device (VPOD) regulates the Variable Nozzle Turbo (VNT). Input values from the ECM/ECU regulates the VPOD air pressure which allows the VNT vanes to change position during engine operation. The VPOD also interfaces with other engine system components. 8.5.1 Removal of Variable Pressure Output Device Removal steps are as follows: PERSONAL INJURY To avoid injury from hot surfaces, wear protective gloves, or allow engine to cool before removing any component. 1. Remove bolt (3) securing air line to oil cooler. See Figure 8-38 2.

Disconnect the air line fittings and remove the air line (4) from the VPOD assembly (1) and VNT actuator (5). See Figure 8-38. 1. VPOD Assembly 3. Bolt 5. VNT Actuator 2. Clip 4. Air Line Figure 8-38 VPOD and Related Parts (Rev. 2005) All information subject to change without notice. 8-44 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION