9.10 WEATHER PACK AND METRI-PACK 280 SERIES CONNECTORS 9.10 WEATHER PACK AND METRI-PACK 280 SERIES CONNECTORS Weather Pack and Metri-Pack 280 series connectors are push-to-seat. The terminal is crimped onto each wire before it is inserted into the connector. A cable seal is crimped on each wire at the same time the terminal is crimped onto the wire. Weather Pack connectors use a secondary lock on both male and female connector bodies and the lock snaps into place over the cable seals after installation. Some Metri-Pack connectors have secondary locks as well.
9.10.1 Repair and Replacement of Weather Pack and Metri-Pack 280 Series Connectors Repairs to Weather Pack and Metri-Pack 280 series connectors are not possible. Remove the defective or damaged connector and replace. Refer to section 9.10.2. 9.10.2 Removal of Weather Pack and Metri-Pack 280 Series Connectors Two locking tangs are used on the terminals to secure them to the connector body. Use the following instructions for removing terminals from the connector body. 1. Grasp the cable to be removed and push the terminal to the forward position. 2. Insert the removal tool straight into the front of the connector cavity until it rests on the cavity shoulder. See Figure 9-37.
Figure 9-37 Removal Tool Procedure 3. Grasp the cable and push it forward through the connector cavity into the tool while holding the tool securely in place. The tool will depress the locking tangs of the terminal. 4. Pull the cable rearward (back through the connector). 5. Remove the tool from the connector cavity. 6. Cut the wire immediately behind the cable seal. (Rev. 2005) All information subject to change without notice. 9-60 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION