SERIES 60 SERVICE MANUAL 7. Follow the installation instructions for crimping the terminal and inserting it into the connector. 9.10.3 Installation of Weather Pack and Metri-Pack 280 Series Connectors Use the following instructions for terminal installation: 1. Slip the cable seal onto the wire. 2. Strip the end of the cable using strippers to leave 5.0 mm ± 0.50 (0.20 in. ± 0.02) of bare connector. 3. See Figure 9-38 to position the cable seal. Figure 9-38 Terminal Position 4. Insert the terminal into the locating hole of the crimping tool using the proper hole according to the gauge of the cable to be used. See Figure 9-39. 5.
Insert the cable into the terminal until the stripped portion is positioned in the cable core wings, and the seal and insulated portion of the cable are in the insulation wings. See Figure 9-39. All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 9-61