Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

SERIES 60 SERVICE MANUAL Carbon Restricted Discharge Line If the discharge line becomes restricted with carbon, the compressor must work harder to deliver compressed air, thus reducing compressor durability. Make sure the discharge line does not have a carbon restriction. Discharge Line Accessories The application of a downstream device such as an air dryer, discharge line unloader, or turbocharger cut-off valve, needs to be installed properly to avoid premature compressor durability problems. Refer to the manufacturer's instructions for these products. NOTE: Alcohol injectors which restrict the flow of air in the discharge line should be avoided.

Restrictions in the discharge line increase the time required to build up system pressure. Compressor Inlet The following summarizes the three compressor inlet connections and the associated pitfalls: Turbocharger: Must be consistent with pressure and speed limits determined by the manufacturer. Inlet side of the turbocharger: Engine air cleaner must be serviced at regular intervals. (See manufacturer's instructions) Local air filter: Local air filter must be serviced at regular intervals. (See manufacturer's instructions) Inlet Connection Recommendations Inlet connection recommendations are as follows: Line size: The preferred inlet size is 19 mm (0.75 in.) I.D.

The minimum line size for the inlet connection is 15.9 mm (0.625 in.) I.D., for either naturally aspirated or turbocharger applications. Depression of inlet pressure: A compressor inlet connected to the engine induction system must not depress the intake pressure to more than 635 mm (25 in. H 2 O). Separate inlet filters: Separate inlet filters must not depress the intake pressure to more than 635 mm (25 in. H 2 O). The polyurethane sponge strainer should be serviced every 8050 km (5000 miles) or 150 operating hours. The paper element type should be replaced every 32,190 km (20,000 miles) or 800 operating hours.

Alcohol Evaporator The alcohol evaporator can be used to reduce the potential for an air system freeze-up; however, it does not remove any moisture from the air system, but only lowers its freezing point. The preferred method of protecting the air system against cold weather freeze-up is with an air dryer. The moisture generated by the compression of air is removed, thus minimizing the possibility of contaminating the air system. All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 11-27