SERIES 60 SERVICE MANUAL 3. Run engine and check for oil leaks from weep hole. [a] If oil leak is observed, remove the water pump and conduct an oil analysis; refer to publication 7SE270 found on the DDC extranet at http://192.135.85.10/support/on- highway/manuals/Lubricants_Fuels_Coolants/7se270.pdf. Then replace water pump as needed. 4. Test and reformulate the coolant to proper glycol and SCA concentrations per the Service Manual Maintenance schedule as indicated in the engine operators guide or DDC publication, 7SE298, available from authorized Detroit Diesel distributors.

14.6.6 Test Procedure for DDEC Engines Equipped with Low Coolant Level Sensor (CLS) The following test procedure is for engine cooling systems that are equipped with a low coolant level sensor mounted in the top tank of the radiator or the heat exchanger. This sensor must be tested annually or every 100,000 miles (161,000 km), whichever comes first. HOT COOLANT To avoid scalding from the expulsion of hot coolant, never remove the cooling system pressure cap while the engine is at operating temperature. Wear adequate protective clothing (face shield, rubber gloves, apron, and boots). Remove the cap slowly to relieve pressure. 1. Allow the engine to cool to ambient temperature. 2.

Turn ignition switch on and verify no coolant level sensor codes. (DO NOT START ENGINE.) 3. Reduce coolant level below CLS level. 4. Check "stop engine light". It should illuminate within 10 seconds, indicating low coolant level. [a] If light illuminates, system is working properly. [b] If light does not illuminate, refer to section 14.6.6.1. 5. Fill coolant to proper level. Refer to section 14.6.4. All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 14-33