Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

14.6 DESCRIPTION OF MAINTENANCE ITEMS 14.6.6.1 Stop Engine Light Did Not Illuminate If "stop engine light" did not illuminate, use the following procedure: 1. Check wiring harness and mating connector for damaged wires or pins. 2. Remove and clean sensor. Wash with mild detergent and rinse with clean water. 3. Submerge sensor in container of water up to connector with wiring harness connected. 4. Turn ignition switch on. (DO NOT START ENGINE.) 5. Slowly remove sensor from water. 6. The light should illuminate, indicating low coolant level. 7. If light does illuminate, system is working properly. 8. If light still does not illuminate, replace sensor and return it to DDC.

14.6.7 Turbocharger Inspect the mountings, intake and exhaust ducting and connections for leaks. Check the oil inlet and outlet lines for leaks and/or restrictions to oil flow. Inspect water-cooled turbochargers for coolant leaks. Inspect impeller blades for oil, excessive sooting and excessive end play. Check for unusual noise or vibration and, if excessive, remove the turbocharger and correct the cause. Refer to section 6.5.2. 14.6.8 Battery On batteries equipped with charge indicator eyes, periodically check for adequate charge. If batteries are the filler-cap type, check the level of the electrolyte every 100 hours or every 12,000 km (7,500 miles).

In warm weather, however, check more frequently due to a more rapid loss of water from the electrolyte. Electrolyte should be maintained in accordance with the recommendations of the battery manufacturer. Periodically remove, check and clean battery post terminals and connections. Replace corroded or damaged parts. Refer to section 9.3.2. (Rev. 2005) All information subject to change without notice. 14-34 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION