14.7 CLEANING CONTAMINATED LUBRICATION OIL SYSTEM 4. Stop the engine and immediately drain the crankcase. Allow enough time to drain all the fluid. Take and label a second oil sample. 5. Repeat steps 1through step 4. 6. Remove and discard all oil filters and replace with new filters. 7. Replace oil drain plugs and pressure fill the engine to the proper level with the lubricating oil recommended for normal operation. 8. Have oil samples analyzed for coolant contamination and condition of the engine. 14.7.3 Flushing an Oil System that Exhibits Gelling Use this procedure if the contaminated oil exhibits gelling.
This requires the lubricating oil recommended for normal operation and the addition of a solvent. FIRE To avoid injury from fire caused by heated diesel-fuel vapors: Keep those people who are not directly involved in servicing away from the engine. Stop the engine immediately if a fuel leak is detected. Do not smoke or allow open flames when working on an operating engine. Wear adequate protective clothing (face shield, insulated gloves and apron, etc.). To prevent a buildup of potentially volatile vapors, keep the engine area well ventilated during operation. 1. Remove and discard all oil filters and replace with new filters.
PERSONAL INJURY To avoid injury from improper use of chemicals, follow the chemical manufacturer’s usage, handling, and disposal instructions. Observe all manufacturer’s cautions. 2. Mix two parts of the lubricating oil recommended for normal operation with one part of butyl cellosolve. Refer to section 5.2 of the service manual for recommended oil. Pressure fill the engine with this mixture to 172 kPa (25 psi) until the crankcase is filled to the proper operating level. (Rev. 2005) All information subject to change without notice. 14-52 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION