1.16 FLYWHEEL 11. Mount a dial indicator with a magnetic base on the flywheel housing. See Figure 1-257. Figure 1-257 Measuring Flywheel Run-out 12. Check the run-out of the flywheel at the clutch contact face. 13. The maximum allowable run-out is 0.0254 mm per millimeter of radius (0.001 in. per inch of radius) total indicator reading per inch of radius (or 0.0254 mm per millimeter of radius). The radius is measured from the center of the flywheel to the outer edge of the clutch contact face of the flywheel. Example: A 14 in. clutch would allow 0.177 mm (0.007 in.) total indicator reading. 14. If maximum total indicator reading exceeds, 0.0254 mm per millimeter of radius (0.001 in.
per inch of radius), it may be necessary to repeat the assembly procedure until the cause can be detected and eliminated. (Rev. 2005) All information subject to change without notice. 1-274 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION