Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

1.23 CYLINDER LINER 11. Measure the distance from the top of the liner flange to the top of the block. See Figure 1-338 [a] Allowable liner protrusion is -0.0127-0.0762 mm (-0.0005-0.003 in.) with no more than 0.0508 mm (0.002 in.) variation between any two adjacent cylinders. Specifications are listed in Table 1-17. [b] If the liner protrusion exceeds the maximum allowable, remove the liner and check for debris under the liner flange. Figure 1-338 Cylinder Liner Protrusion 12. Remove the cylinder liner tool. 13. With all of the cylinder liners installed and the liner protrusion measurements within specifications, install the piston and connecting rod assemblies. Refer to section 1.21.5. (Rev.

2005) All information subject to change without notice. 1-372 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION