4. Inspect flange bolt holes visually and determine if any necessary repairs can be made by chasing threads or installing heli-coil(s). 5. Regardless of seal area wear condition, a new sleeve and seal must be installed. 6. Read and record all "bearing" total indicator reading (TIR) measurements with the crankshaft mounted in vee blocks. Listed in Table 1-12 are TIR limits. NOTE: Run-out tolerance listed in Table 1-12 are given for guidance when regrinding crankshaft. When the run-out on adjacent journals is in the opposite direction, the sum must not exceed 0.076 mm (0.003 in.) total indicator reading.
When the run-out on adjacent journals is in the same direction, the difference must not exceed 0.076 mm (0.003 in.) total indicator reading. Table 1-12 Bearing Total Indicator Reading (TIR) Specifications 7. Whether run-out on adjacent journals is in the same or opposite directions, the sum shall not exceed 0.076 mm (0.003 in.) TIR. 8. When high spots of run-out adjacent journals are at right angles to each other, the sum shall not exceed 0.10 mm (0.004 in.) TIR or 0.05 mm (0.002 in.) on each journal. (Rev. 2005) All information subject to change without notice.
1-644 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION Journals Supported On Journals Measured Maximum Run-Out (Total Indicator Reading) No. 1 and No. 7 No. 2 and No. 6 0.076 mm (0.003 in.) No. 1 and No. 7 No. 3 and No. 5 0.127 mm (0.005 in.) No. 1 and No. 7 No. 4 0.152 mm (0.006 in.)