2.2 VEHICLE SAFETY FOR THE NATURAL GAS ENGINE 2.2.2 Safety Standards Products manufactured for the NGV industry - from under-hood components to fuel-pump nozzles - are governed by a variety of standards to ensure safety. For example, onboard components including pressure regulators, valves, fueling nozzles and connectors, etc., must be certified by International Approval Services, jointly sponsored by American Gas Association Labs and Canadian Gas Association Labs. The National Fire Protection Association (NFPA) has created a safety standard (NFPA 52) for equipment installation and fueling infrastructure. The Uniform Fire Code (Article 52, Standard No.

52-1) also addresses NGV safety issues relating to fueling stations, including fueling indoors. The Compressed Gas Association has numerous standards pertaining to cylinders. Through several NGV Coalition committees, the industry has created a series of strict voluntary standards and continues to improve and add to these. Standards for fueling connectors and cylinders are already on the books (known as ANSI/NGV1 and ANSI/NGV2, respectively). As a fleet operator, you needn't become a NGV standards expert, but you can rest assured the industry is working hard to address safety concerns and ensure NGVs perform as safe and safer than conventional vehicles.

As you introduce NGVs to your fleet and need to know more about which safety standards apply to your operation, consult your gas company representative. Your gas company probably has several NGVs in its fleet and has worked with local officials on meeting codes. If your local fire marshal isn't familiar with NGVs, your gas company representative in many cases can put him or her in touch with someone who is. 2.2.3 Cylinder Safety Fuel for NGVs is stored in cylinders under pressure, typically at 20,685 or 24,820 kPa (3,000 or 3,600 psi). To the uninitiated this sounds hazardous just by definition.

As one industry report notes, "There is no doubt that carrying a highly pressurized fuel onboard a vehicle represents a ‘high perceived risk' which simply does not occur on conventionally fueled vehicles." The NGV industry, to its credit, has made addressing any risks, perceived or real, a top priority, and this is particularly evident in the area of storage container (cylinder) safety. In recent years the industry has developed strict voluntary standards for cylinders in conjunction with governmental bodies such as the American National Standards Institute (ANSI).

In 1994, the National Highway Traffic Safety Administration (NHTSA) adopted a set of regulations (known as DOT 304) governing cylinder durability, strength and pressure relief. The regulations also set testing criteria and generally follow the industry's existing ANSI/NGV2 standard. In the future NHTSA will codify additional standards, including cylinder resistance to chemical corrosion. Cylinders undergo a variety of rigorous tests. In the bonfire test, as its name suggests, a pressurized cylinder is subjected to flames of around 649°C (1,200°F) to determine its resistance to bursting. To pass the test, the cylinder must remain intact long enough to safely release its contents.

A pressure-relief device, required by NHTSA rules, vents the contents when the cylinder reaches about 99°C (210°F) to 104°C (220°F), and the cylinder typically remains intact for another 100 degrees beyond that. Cylinders must also pass a pressure test that subjects them to 18,000 cycles of pressurization and depressurization. (Rev. 2005) All information subject to change without notice. 2-8 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION