Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

SERIES 60 SERVICE MANUAL 2.20.3 Installation of Electronic Distributor Unit Install the EDU as follows: 1. Install the screws securing the cold plate to the EDU. Use Loctite® 262, or equivalent, on the cold plate-to-EDU screws. Torque to 9.5-12 N·m (84-106 lb·in.). 2. Install the cold plate to the EDU. 3. Install the EDU and cold plate to the engine. 4. Install the through-bolts and washers holding the EDU to the engine. Torque the EDU-to-engine bolts to 30-38 N·m (22-28 lb·ft). Torque the EDU connector hold down screws to 2.4-3.0 N·m (21-26 lb·in.). NOTE: Torque the harness connector to EDU screws to 2.4-3.0 N·m (21-26 lb·in.). 5. Connect the inlet and return lines to the EDU cold plate. 6.

Connect the fuel line (at the secondary fuel filter) that runs from the EDU cold plate. 7. Turn the ignition to the ON position. Observe the DDR for any diagnostic code(s). If any code(s) other than code 25 is logged, refer to the Detroit Diesel Single ECM Troubleshooting Manual (6SE497). PERSONAL INJURY To avoid injury before starting and running the engine, ensure the vehicle is parked on a level surface, parking brake is set, and the wheels are blocked. PERSONAL INJURY Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm. Always start and operate an engine in a well ventilated area.

If operating an engine in an enclosed area, vent the exhaust to the outside. Do not modify or tamper with the exhaust system or emission control system. 8. Start the engine and check for fuel leaks. Shut down upon completion of test. All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 2-171