SERIES 60 SERVICE MANUAL 2.27.3 Installation of Air Temperature Sensor Install the ATS as follows: NOTICE: Overtightening will distort and crack the sensor body, resulting in sensor malfunction. Damage may not be evident until sensor removal, when body may break apart. 1. If installing a new ATS, there is no need to use sealer as it is applied during manufacturing. When reinstalling a serviceable ATS, apply Loctite® pipe sealant with Teflon PT-7260 or equivalent on all but first two threads. 2. Install ATS to the intake manifold (diesel) or air inlet tube (natural gas). NOTE: Because of its plastic body, the ATS must be hand started and carefully tightened. 3. Torque to 11-16 N·m (8-12 lb·ft).
4. Carefully fasten connector onto sensor and engage locking tang. 5. Turn the ignition to the ON position. Observe the DDR for any diagnostic code(s). If any code(s) other than code 25 is logged, refer to the Detroit Diesel Single ECM Troubleshooting Manual (6SE497). All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 2-187