Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

SERIES 60 SERVICE MANUAL 2.42 VENTING AND LEAK CHECKING PROCEDURES FOR A NATURAL GAS ENGINE (HIGH PRESSURE SYSTEM) To vent and leak check an operable engine, refer to section 2.42.1. 2.42.1 Venting an Operable Engine to Relieve Natural Gas Pressure Vent an operable engine as follows: EXPLOSION To avoid injury from the explosion of natural gas, the engine must be kept in a well ventilated area away from open flames, sparks, and electrical resistance (heating) coils. 1. Shut off manual valves on natural gas supply tanks and main shutoff valve on natural gas fuel supply line. 2. Start engine and run until it stalls due to fuel starvation. 3.

Check to ensure gage pressure at point on the natural gas fuel line to be vented has been reduced to zero. If not, repeat step 1. Then repeat step 2. 4. Disconnect the vehicle batteries using switch(s) in the battery compartment or by disconnecting battery ground cable. 5. Slightly loosen the CNG fuel line fitting to be serviced in a well-ventilated area to allow any remaining gas to vent. 6. Completely open the fitting that was slightly opened and allow to vent in a well-ventilated area. All information subject to change without notice. (Rev. 2005) 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION 2-225