Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

2.42 VENTING AND LEAK CHECKING PROCEDURES FOR A NATURAL GAS ENGINE (HIGH PRESSURE SYSTEM) 2.42.2 Venting an Inoperable Engine to Relieve Natural Gas Pressure If the engine cannot run , use the following venting procedure to relieve the natural gas pressure downstream of the shutoff valve: EXPLOSION To avoid injury from the explosion of natural gas, the engine must be kept in a well ventilated area away from open flames, sparks, and electrical resistance (heating) coils. 1. Shut off manual valves on natural gas supply tanks and main shutoff valve on natural gas fuel supply line. 2.

Disconnect the vehicle batteries using switch(s) in the battery compartment or by disconnecting the battery ground cable. 3. Open a fitting to assure all pressure has been relieved in the natural gas vehicle fuel line. 4. Check all connections that were loosened for leaks after installation, service and troubleshooting are complete. (Rev. 2005) All information subject to change without notice. 2-226 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION