Detroit Diesel — Print Preview - C:\DOCUME~1\llakso01\LOCALS~1\Temp\.aptcache\S600507006\S600507

2.43 HIGH PRESSURE FUEL REGULATOR FOR THE SERIES 60G ENGINE 2.43.1 Replacement of the High Pressure Regulator for the Series 60G Engine The high pressure fuel regulator is not serviceable and should be replaced as a unit. No adjustment is required. 2.43.2 Removal of the High Pressure Regulator for the Series 60G Engine Remove the high pressure fuel regulator as follows: 1. Vent fuel system, refer to section 2.51. 2. Disconnect fuel supply pipe at regulator inlet. 3. Disconnect fuel pipe from regulator outlet. 4. Drain coolant. 5. Disconnect coolant supply and return hoses at regulator. 6. Disconnect vent pipe at regulator. 7.

Remove two M8 bolts attaching the regulator to its mounting bracket. 8. Remove regulator from bracket and remove fittings for reuse. 2.43.3 Installation of the High Pressure Regulator for the Series 60G Engine Install the high pressure fuel regulator as follows: 1. Install gas inlet and outlet O-ring fittings. 2. Position regulator on mounting bracket. 3. Install two M8 mounting bolts. 4. Connect fuel outlet pipe. 5. Connect fuel supply pipe. 6. Connect coolant supply and return hoses. 7. Refill with coolant. 8. Connect vent pipe. 9. Open fuel shutoff valves and crank engine to supply fuel to regulator. 10. Check for leaks, refer to section 2.50. (Rev.

2005) All information subject to change without notice. 2-230 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION