2.44 PULSE WIDTH MODULATED STEPPER MOTOR VALVE (PSV) FOR SERIES 60G AUTOMOTIVE ENGINES 2.44.1 Replacement of Pulse Width Modulated Stepper Motor Valve for the Series 60G Engine The PSV is non-serviceable and should be replaced as a unit. No adjustment is required. 2.44.2 Removal of Pulse Width Modulated Stepper Motor Valve for the Series 60G Engine Remove the PSV as follows: To avoid injury from the explosion of natural gas, the engine must be kept in a well ventilated area away from open flames, sparks, and electrical resistance (heating) coils. EXPLOSION 1. Vent fuel system; refer to section 2.51. 2. Disconnect the seven-wire connector from the engine sensor wiring harness. 3.
Remove the four bolts connecting the PSV to the fuel mixer. 4. Slide the PSV forward to separate from the connecting tube. 2.44.3 Installation of Pulse Width Modulated Stepper Motor Valve for the Series 60G Engine Install the PSV as follows: 1. Lubricate connector O-rings and PSV O-ring. 2. Loosen bolts attaching fuel mixer to throttle. NOTE: The bolt holes in the throttle are slotted to allow adjustment to align the PSV with the connector tube in the low pressure regulator. 3. Position PSV against the mixer with O-ring in place and align gas inlet port with connector. Slide rearward to engage connector until bolts holes are aligned. 4.
Secure PSV to the fuel mixer with four bolts and torque to 20 N·m (15 lb·ft). 5. Tighten fuel mixer to throttle attaching bolts. (Rev. 2005) All information subject to change without notice. 2-232 6SE483 0507 Copyright © 2005 DETROIT DIESEL CORPORATION