Komatsu — WHEN REQUIRED

. MAINTENANCE SERVICE PROCEDURE CLEAN INSIDE OF COOLING SYSTEM WARNING The coolant has the important function of preventing corrosion as well as preventing freezing. Even in the areas where freezing is not an issue, the use of antifreeze coolant is essential. Komatsu machines are supplied with Komatsu Supercoolant (AF-NAC). Komatsu Supercoolant (AF-NAC) has excellent anticorrosion, antifreeze and cooling properties and can be used continuously for 2 years or 4000 hours. As a basic rule, we do not recommend the use of any coolant other than Komatsu genuine supercoolant (AF-NAC).

If you use another coolant, it may cause serious problems, such as corrosion of the engine and aluminum parts of the cooling system. To maintain the anticorrosion properties of Supercoolant (AF-NAC), always keep the density of Supercoolant between 30% and 68%. When deciding the ratio of antifreeze to water, check the lowest temperature in the past, and decide from the mixing table given below. It is actually better to estimate and temperature about 10 ° C (18 ° F) lower when deciding the mixing ratio. The mixing ratio depends on the ambient temperature, but it should always be a minimum of 30% by volume (antifreeze/total amount of coolant x 100).

Even in areas where it is not necessary to prevent freezing, use Supercoolant (AF-NAC) at a mixing ratio of at least 30% to prevent corrosion of the cooling system. The freezing temperature of undiluted antifreeze is -15 ° C (5 ° F). Do not store undiluted antifreeze at a temperature of below -15 ° C (5 ° F). 4 - 27 Just af ter the engin e is stopped, t he coolant is stil l hot and the i nternal pressure in t he radiato r is still high. If the radiator cap is remo ved under t his condition, you may scald yo urself. Accordingly, wait until the temperature goes down, the n loosen the cap slo wly to relea se the p ressur e. Start th e engine to clean th e cool ing system.

Whe n standing up from th e operator's seat or leaving the machine, set the work equipm ent lock lev er and parking brake l ever to th e LOCK positions. For the starting m ethod o f the e ngine, see "CHE CK BEFORE STARTING ENGINE ENGIN E (PAGE 3-8 4)" in th e OPERATION section of the manual Never go under the machi ne bod y while t he engin e is running. I t is very dangerous since the machine may move suddenly. and "STARTING Stop the machine o n level groun d whe n cleanin g or changing the coolant. Clean th e inside of the cooling s ystem, change the coolant according to the t able below.

In Antifreeze coolant terval for cleaning inside of cooling system and changing antifreeze coolant Komatsu supercoolant (AF-NAC) Every two years or every 4000 hours whichever comes first