Kubota L3240, L3540, L3940, L4240, L4740, L5040, L5240, L5740 — Remote Control Valve

69 HYDRAULIC UNIT REMOTE HYDRAULIC CONTROL SYSTEM (if equipped) B Remote Control Valve Coupler Connecting and Disconnecting To avoid personal injury: A Stop the engine and relieve pressure before connecting or disconnecting lines. A Do not use your hand to check for leaks. C Connecting 1. Clean both couplers. 2. Remove dust plugs. 3. Insert the implement coupler to the tractor hydraulic coupler. 4. Pull the implement coupler slightly to make sure couplers are firmly connected. (1)(2)(3) Remote control valve lever (X) "FORWARD" (Y) "REARWARD" Pressure C Disconnecting 1. Lower the implement first to the ground to release hydraulic pressure in the hoses. 2. Clean the couplers. 3.

Relieve pressure by moving hydraulic control levers with engine shut off. Pull the hose straight from the hydraulic coupler to release it. 4. Clean oil and dust from the coupler, then replace the dust plugs. Returning A Your local KUBOTA Dealer can supply parts to adapt couplers to hydraulic hoses. B Remote Control Valve Lever Move the lever to the "FORWARD" or "REARWARD" position and hold. This will raise or lower the implement. Lever will return to neutral when released. A Do not hold the lever in the "REARWARD" or "FORWARD" position once the remote cylinder has reached the end of the stroke, as this will cause oil to flow through the relief valve.

Forcing oil through the relief valve for extended periods will overheat the oil. A When using the tractor hydraulic system to power front loader, do not operate boom and bucket cylinders simultaneously. B Remote Control Valve There are two types of remote valves available for these models. A Double acting valve: A Double acting valve with float position: This valve may be placed in the float mode with the control lever all the way forward. The cylinder is free to extend or retract, letting an implement such as a loader bucket follow the ground.

Lever (1) Forward Rearward Port [A] In Out [B] Out In Lever (2) Forward Rearward Port [C] In Out [D] Out In Lever (3) Forward Rearward Port [E] In Out [F] Out In Coupler size Port [A] [B] PT 1/2 Port [C] [D] Port [E] [F]