Perkins — Perkins 402F-05, 403F-07, 403F-11, 403F-15 Industrial Engines Operation and Maintenance Manual

Refill Capacities Fluid Recommendations 46 SEBU9064 Table 25 (1) This specification includes the requirements for Ultra Low Sulfur Diesel (ULSD). ULSD fuel will have ≤15 ppm (0.0015%) sulfur. Refer to ASTM D5453, ASTM D2622, or ISO 20846, ISO 20884 test methods. (2) A fuel with a higher cetane number is recommended in order to operate at a higher altitude or in cold weather. (3) “Via standards tables, the equivalent API gravity for the minimum density of 801 kg / m 3 (kilograms per cubic meter) is 45 and for the maximum density of 876 kg / m 3 is 30”. (4) The values of the fuel viscosity are the values as the fuel is delivered to the fuel injection pumps.

Fuel should also meet the minimum viscosity requirement and the fuel should meet the maximum viscosity requirements at 40 °C (104 °F) of either the ASTM D445 test method or the ISO 3104 test method. If a fuel with a low viscosity is used, cooling of the fuel may be required to maintain “1.4 cSt”or greater viscosity at the fuel in- jection pump. Fuels with a high viscosity might require fuel heaters in order to lower the viscosity to “1.4 cSt” at the fuel injection pump. (5) Follow the test conditions and procedures for gasoline (motor). (6) The lubricity of a fuel is a concern with ultra low sulfur fuel.

To determine the lubricity of the fuel, use the ISO 12156-1 or ASTM D6079 High Frequency Reciprocating Rig (HFRR) test. If the lubricity of a fuel does not meet the minimum requirements, consult your fuel supplier. Do not treat the fuel without consulting the fuel supplier. Some additives are not compatible. These additives can cause problems in the fuel system.

Perkins Specification for Distillate Diesel Fuel(1) Property UNITS Requirements ASTMTest ISOTest Aromatics %Volume 35% maximum D1319 ISO3837 Ash %Weight 0.01% maximum D482 ISO6245 Carbon Residue on 10% Bottoms %Weight 0.35% maximum D524 ISO4262 Cetane Number (2) - 40 minimum D613/D6890 ISO5165 Cloud Point °C The cloud point must not ex- ceed the lowest expected ambient temperature. D2500 ISO3015 Copper Strip Corrosion - No.

3 maximum D130 ISO2160 Density at 15 °C (59 °F)(3) Kg / M3 801 minimum and 876 maximum No equivalent test ISO 3675ISO 12185 Distillation °C 10% at 282 °C (539.6 °F) maximum 90% at 360 °C (680 °F) maximum D86 ISO3405 Flash Point °C legal limit D93 ISO2719 Thermal Stability - Minimum of 80% reflectance after aging for 180 minutes at 150 °C (302 °F) D6468 No equivalent test Pour Point °C 6 °C (42.8 °F) minimum be- low ambient temperature D97 ISO3016 Sulfur (1) %mass 0.0015 D5453/D26222 ISO 20846ISO 20884 Kinematic Viscosity (4) “MM”2“/S (cSt)” The viscosity of the fuel that is delivered to the fuel injec- tion pump.

“1.4 minimum/ 4.5 maximum” D445 ISO3405 Water and sediment % weight 0.1% maximum D1796 ISO3734 Water % weight 0.1% maximum D1744 No equivalent test Sediment % weight 0.05% maximum D473 ISO3735 Gums and Resins (5) mg/100mL 10 mg per 100 mL maximum D381 ISO6246 Lubricity corrected wear scar diameter at 60 °C (140 °F). (6) mm 0.52 maximum D6079 ISO12156-1