80 SEBU9064 Maintenance Recommendations Starting Motor - Inspect If the radiator is blocked internally, refer to the OEM Manual for information regarding flushing the cooling system. NOTICE For any type of leak (coolant, lube, or fuel) clean up the fluid. If leaking is observed, find the source and correct the leak. If leaking is suspected, check the flu- id levels more often than recommended until the leak is found or fixed, or until the suspicion of a leak is proved to be unwarranted. After cleaning the radiator, start the engine. Allow the engine to operate at low idle speed for three to five minutes. Accelerate the engine to high idle.

This will help in the removal of debris and the drying of the core. Slowly reduce the engine speed to low idle and then stop the engine. Use a light bulb behind the core in order to inspect the core for cleanliness. Repeat the cleaning, if necessary. NOTICE Accumulated grease and/or oil on an engine is a fire hazard. Remove the accumulated grease and oil. Re- fer to this Operation and Maintenance Manual, “En- gine - Clean” for more information. Inspect the fins for damage. Bent fins may be opened with a “comb”. Inspect these items for good condition: Welds, mounting brackets, air lines, connections, clamps and seals. Make repairs, if necessary.

i02177969 Starting Motor - Inspect Ensure that the cooling system hoses are correctly clamped and that the cooling system hoses are tight. Check for leaks. Check the condition of all pipes. Inspect the water pump for coolant leaks. Perkins recommends a scheduled inspection of the starting motor. If the starting motor fails, the engine may not start in an emergency situation. Note: The water pump seal is lubricated by the coolant in the cooling system. It is normal for a small amount of leakage to occur as the engine cools down and the parts contract. Check the starting motor for correct operation. Check the electrical connections and clean the electrical connections.

Refer to the Systems Operation, Testing and Adjusting Manual, “Electric Starting System - Test” for more information on the checking procedure and for specifications or consult your Perkins dealer or your Perkins distributor for assistance. Excessive coolant leakage may indicate the need to replace the water pump seal. For the removal of the water pump and the installation of water pump and/or seal, refer to the Disassembly and Assembly Manual, “Water Pump - Remove and Install” for more information or consult your Perkins dealer or your Perkins distributor.

i02177973 Walk-Around Inspection Inspect the lubrication system for leaks at the front crankshaft seal, the rear crankshaft seal, the oil pan, the oil filters and the rocker cover. Inspect the Engine for Leaks and for Loose Connections Inspect the fuel system for leaks. Look for loose fuel line clamps and/or tie-wraps. A walk-around inspection should only take a few minutes. When the time is taken to perform these checks, costly repairs and accidents can be avoided. Inspect the piping for the air intake system and the elbows for cracks and for loose clamps. Ensure that hoses and tubes are not contacting other hoses, tubes, wiring harnesses, etc.

For maximum engine service life, make a thorough inspection of the engine compartment before starting the engine. Look for items such as oil leaks or coolant leaks, loose bolts, worn belts, loose connections and trash buildup. Make repairs, as needed: Inspect the alternator belts and any accessory drive belts for cracks, breaks or other damage. Belts for multiple groove pulleys must be replaced as matched sets. If only one belt is replaced, the belt will carry more load than the belts that are not replaced. The older belts are stretched. The additional load on the new belt could cause the belt to break. The guards must be in the correct place. Repair damaged guards or replace missing guards.

Wipe all caps and plugs before the engine is serviced in order to reduce the chance of system contamination.