hyundai R510LC-7 — 3. ELECTRICAL SYSTEM

10. WHEN SAFETY SOLENOID DOES NOT OPERATE Before disconnecting the connector, always turn the starting switch OFF. Before carrying out below procedure, check all the related connectors are properly inserted and short of fuse No.26. After checking, insert the disconnected connectors again immediately unless otherwise specified. SAFETY SWITCH EARTH 1 CS-20 SAFETY SWITCH 7 SAFETY SOLENOID 8 CS-4 CN-4 CN-68 FUSE NO.26 51076ES05 6-33 YES YES Check operation of solenoid Safety lever : ON-OFF NO YES Check voltage YES between CS-4(C) Check voltage and chassis between CN- 68(1) - CN-68(2) Start switch : ON NO YES Check voltage Voltage : 20~30V Starting switch :

ON between CN-4(8) Disconnect CN-4 Voltage : 20~30V and chassis Safety state Starting switch : ON Voltage : 20~30V Disconnect CN-4 Check voltage NO between CN-68(2) NO with chassis Safety lever : OFF Starting switch : ON Voltage : 20~30V NO Cause Remedy Hydraulic malfunction Defective solenoid Defective switch Disconnection in wiring harness or poor contact between CS-4(C)-CN-68(2) Disconnect in wiring harness or poor contact between CN-4(8)-CN-68(2) Disconnection in fuse No. 26 Check hydraulic system Replace Replace Repair or replace (After clean) Repair or replace (After clean) Replace B C A A B C 2 1