11. WHEN TRAVEL SPEED 1, 2 DOES NOT OPERATE Before disconnecting the connector, always turn the starting switch OFF. Before carrying out below procedure, check all the related connectors are properly inserted and short of fuse No.24 . After checking, insert the disconnected connectors again immediately unless otherwise specified. YES YES Check voltage between CN-50 (13) and chassis YES YES Check operation of solenoid Check resistance between CN-70 (1) and (2) Check if travel speed lamps( , ) change when pressing the travel speed switch on the cluster Starting switch : ON Voltage : 20~30V Disconnect CN-50 Starting switch : ON : OFF : ON NO Starting switch : OFF SPEC :
15~25 NO Disconnect CN-70 Starting switch : ON Check controller YES NO R Y G NO Starting switch : ON 45076ES03 6-34 Cause Remedy Defective hydraulic ystem Defective controller Defective solenoid Defective cluster Defective controller Check hydraulic system Replace Replace Replace Replace