Specific gravity : MIN 1.28 Voltage : MIN 24V Check voltage and specific gravity of battery 13. WHEN STARTING SWITCH ON DOES NOT OPERATE After checking, insert the disconnected connectors again immediately unless otherwise specified. Before carrying out below procedure, check all the related connectors are properly inserted and master switch ON. Before disconnecting the connector, always turn the starting switch OFF.
YES NO YES CS-74 Check voltage between DO-2 (1) and chassis YES Disconnection in wiring harness or poor contact between DO-2(1)- CR-1 or defective battery relay Cause Remedy Repair or replace (After clean) 6-36 1 2 50076ES08 YES YES Check voltage between DO-2 (1) and chassis Voltage : 20~30V YES Check voltage NO between CS-2 (2) and chassis Voltage : 20~30V Check voltage YES Starting switch : ON between CS-2(1) and chassis Voltage : 20~30V NO Check voltage and specific NO gravity of battery Specific gravity : MIN 1.28 Voltage :
MIN 24V NO Cause Remedy Disconnection in wiring harness or poor contact between DO-2(1)- CR-1 or defective battery relay Disconnection in wiring harness or poor contact between CS-2(2)- CN-8(11)- DO-2(1) Defective starting switch Disconnection in wiring harness or poor contact between CS-2(1)- CN-8(12)-CN-60- CR-1-Battery Battery capacity too Repair or replace (After clean) Replace Replace Replace Charge or replace