(3) Arm recycling (arm in) When the arm is at in position, the spool(S5-6) stroke against the passage(S5-2) pressure guided from the passage(S5-5) is changed according to the opening angle of arm recycling orifice(Lc8). When the pressure of the passage(S5-2) is high and this stroke is increased, the opening angle of orifice(Lc8) become large. On the contrary, when the pressure of passage(S5-2) is low, this stroke is decreased, the opening angle of orifice(Lc8) become small. Therefore, the flow rate for arm recycling is changed by the pressure in bottom side of arm cylinder. 45071MC11 2-36