BF135A•BF150A • ECT Sensor 1 Troubleshooting 3. ECT sensor 1 line short circuit check -1. Turn the ignition switch OFF and disconnect the ECM connector B. -2. Check for the continuity between the No.2 (Red/White) terminal of the ECT sensor 1 harness side 2P con- nector and the body ground. MIL comes ON 6 times. 1. Symptom reproduction test -1. Reset the ECM. -2. Turn the ignition switch OFF and connect the test har- ness. Hold the sensor connector connected. -3. Turn the ignition switch ON. -4. Measure the voltage between the test harness B-8 ter- minal (+) and the A-2 terminal (–).
ECT SENSOR 1 HARNESS SIDE 2P CONNECTOR TE (RED/WHITE) A-2 B-8 VIEWED FROM THE TERMINAL SIDE Is there the continuity? YES – Repair short in the wire between the ECM and the ECT sensor 1. NO – Perform "4. ECT sensor 1 ground line short circuit check". Is the measured voltage 0.22 – 3.15V? YES – Temporary failure (Disappeared) NO – Perform "2. ECT sensor 1 signal line open cir- cuit check". 2. ECT sensor 1 signal line open circuit check -1. Turn the ignition switch ON. Measure the voltage between the No. 2 (Red/White) terminal of the ECT sensor 1 harness side 2P connector and the engine ground. 4. ECT sensor 1 ground line short circuit check -1. Turn the ignition switch OFF.
Check for the continuity between the No. 1 (Green/Red) terminal of the ECT sensor 1 harness side 2P connector and the engine ground. ECT SENSOR 1 HARNESS SIDE 2P CONNECTOR ECT SENSOR 1 HARNESS SIDE 2P CONNECTOR TE (RED/WHITE) SG2 (GREEN/RED) VIEWED FROM THE TERMINAL SIDE VIEWED FROM THE TERMINAL SIDE Is there the continuity? YES – Perform the 5. ECT sensor 1 check. NO – Repair open in the wire between the ECM and the ECT sensor. Is the measured voltage 4.30 – 5.25V? YES – Perform "3. ECT sensor 1 line short circuit check". NO – Repair open in the wire between the ECM and ECT sensor 1. 5-74