BF135A•BF150A 6. CMP sensor check -1. Reset the ECM. -2. Start the engine and let it run at idling under no load. Check the MIL. • IAT Sensor Troubleshooting MIL blinks 10 times. 1. Symptom reproduction check -1. Reset the ECM. -2. Turn the ignition switch OFF and connect the test har- ness. Hold the sensor connector connected. -3. Turn the ignition switch ON. -4. Measure the voltage between the B-11 terminal (+) and the A-2 terminal (-) of the test harness. Does the MIL come ON? YES – Replace the CMP sensor and recheck. If the MIL comes ON again, substitute a known- good ECM and recheck. NO – End of the check A-2 B-11 Is the voltage 0.08 – 4.92V?
YES – Temporary failure (Disappeared) NO – Perform "2. IAT sensor signal line open circuit check". 2. IAT sensor signal line open circuit check -1. Turn the ignition switch OFF and disconnect the IAT sensor 2P connector. -2. Turn the ignition switch ON. Measure the voltage between the No. 2 (Red/Yellow) terminal of the IAT sensor harness side 2P connector and the engine ground. IAT SENSOR HARNESS SIDE 2P CONNECTOR TA (RED/YELLOW) VIEWED FROM THE TERMINAL SIDE Is the voltage 4.75 – 5.25V? YES – Perform “3. IAT sensor signal line short circuit check”. NO – Repair open in the wire between the IAT sen- sor and the ECM. 5-78